High-temperature combustion plant Hünxe
High-temperature combustion plant for the incineration of hydrocarbon-charged exhaust air
Application:
Pressureless exhaust air from tanks, which is generated at the cleaning and filling of tankers.
Plant description:
The high-temperature chamber must incinerate the A1-A3-steam-air-mixtures in the below described operation range in an environmentally compatible way. The gaseous mixture is drawn off the tank with a adequate, pressure shock resistant gas compressor and then led with sufficient pressure to the C-nox high-temperature combustion chamber. The C-nox high-temperature combustion chamber starts fully automatically when switched on. As inert gaseous mixtures with a low hydrocarbon load can occur, an auxiliary burner on the basis of propane is integrated.
Technical data:
Volume flow gaseous mixture: 600 m3/h
Load: 0 - 350 g/m3
Pressure: 1.000 mbar
Firing power: 1.315 kW